Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Front Med (Lausanne) ; 11: 1337367, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38327708

RESUMEN

Following kidney transplantation, lifelong immunosuppressive therapy is essential to prevent graft rejection. On the downside, immunosuppression increases the risk of severe infections, a major cause of death among kidney transplant recipients (KTRs). To improve post-transplant outcomes, adequate immunosuppressive therapy is therefore a challenging but vital aspect of clinical practice. Torque teno virus load (TTVL) was shown to reflect immune competence in KTRs, with low TTVL linked to an elevated risk for rejections and high TTVL associated with infections in the first year post-transplantation. Yet, little is known about the dynamics of TTVL after the first year following transplantation and how TTVL changes with respect to short-term modifications in immunosuppressive therapy. Therefore, we quantified TTVL in 106 KTRs with 108 clinically indicated biopsies, including 65 biopsies performed >12 months post-transplantation, and correlated TTVL to histopathology. In addition, TTVL was quantified at 7, 30, and 90 days post-biopsy to evaluate how TTVL was affected by changes in immunosuppression resulting from interventions based on histopathological reporting. TTVL was highest in patients biopsied between 1 and 12 months post-transplantation (N = 23, median 2.98 × 107 c/mL) compared with those biopsied within 30 days (N = 20, median 7.35 × 103 c/mL) and > 1 year post-transplantation (N = 65, median 1.41 × 104 c/mL; p < 0.001 for both). Patients with BK virus-associated nephropathy (BKVAN) had significantly higher TTVL than patients with rejection (p < 0.01) or other pathologies (p < 0.001). When converted from mycophenolic acid to a mTOR inhibitor following the diagnosis of BKVAN, TTVL decreased significantly between biopsy and 30 and 90 days post-biopsy (p < 0.01 for both). In KTR with high-dose corticosteroid pulse therapy for rejection, TTVL increased significantly between biopsy and 30 and 90 days post-biopsy (p < 0.05 and p < 0.01, respectively). Of note, no significant changes were seen in TTVL within 7 days of changes in immunosuppressive therapy. Additionally, TTVL varied considerably with time since transplantation and among individuals, with a significant influence of age and BMI on TTVL (p < 0.05 for all). In conclusion, our findings indicate that TTVL reflects changes in immunosuppressive therapy, even in the later stages of post-transplantation. To guide immunosuppressive therapy based on TTVL, one should consider inter- and intraindividual variations, as well as potential confounding factors.

2.
Infect Genet Evol ; 119: 105577, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38403035

RESUMEN

In January 2021, the monitoring of circulating variants of SARS-CoV-2 was initiated in Germany under the Corona Surveillance Act, which was discontinued after July 2023. This initiative aimed to enhance pandemic containment, as specific amino acid changes, particularly in the spike protein, were associated with increased transmission and reduced vaccine efficacy. Our group conducted whole genome sequencing using the ARTIC protocol (currently V4) on Illumina's NextSeq 500 platform (and, starting in May 2023, on the MiSeq DX platform) for SARS-CoV-2 positive specimen from patients at Heidelberg University Hospital, associated hospitals, and the public health office in the Rhine-Neckar/Heidelberg region. In total, we sequenced 26,795 SARS-CoV-2-positive samples between January 2021 and July 2023. Valid sequences, meeting the requirements for upload to the German electronic sequencing data hub (DESH) operated by the Robert Koch Institute (RKI), were determined for 24,852 samples, and the lineage/clade could be identified for 25,912 samples. The year 2021 witnessed significant dynamics in the circulating variants in the Rhine-Neckar/Heidelberg region, including A.27.RN, followed by the emergence of B.1.1.7 (Alpha), subsequently displaced by B.1.617.2 (Delta), and the initial occurrences of B.1.1.529 (Omicron). By January 2022, B.1.1.529 had superseded B.1.617.2, dominating with over 90%. The years 2022 and 2023 were then characterized by the dominance of B.1.1.529 and its sublineages, particularly BA.5 and BA.2, and more recently, the emergence of recombinant variants like XBB.1.5. Since the global dominance of B.1.617.2, the identified variant distribution in our local study, apart from a time delay in the spread of new variants, can be considered largely representative of the global distribution. om a time delay in the spread of new variants, can be considered largely representative of the global distribution.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , COVID-19/epidemiología , Alemania/epidemiología , Hospitales Universitarios
3.
Transplantation ; 107(12): e363-e369, 2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-37798825

RESUMEN

BACKGROUND: Quantification of torque teno virus (TTV) has been proposed as a surrogate parameter to monitor immunocompetence in kidney transplant recipients (KTRs) early after transplantation. However, its use in monitoring short-term changes of immunosuppression in KTRs late after transplantation requires further investigation. METHODS: In this post hoc analysis, we quantified TTV load in sera of 76 KTRs, with 43 pausing mycophenolic acid (MPA) 1 wk before to 4 wk after COVID-19 vaccination to increase vaccine response. TTV load was quantified before, 4 wk, and 3 mo postvaccination. Results were compared to 33 KTRs with continued standard immunosuppressive therapy and with 18 hemodialysis as well as 18 healthy control subjects. RESULTS: TTV load before vaccination was with a median (interquartile range) of 1.39 × 10 4 copies/milliliter (c/mL) (9.17 × 10 1 -2.66 × 10 5 c/mL) highest in KTRs compared to 1.73 × 10 3 c/mL (1.07 × 10 3 -1.31 × 10 4 c/mL) in hemodialysis patients and 1.53 × 10 2 c/mL (6.38-1.29 × 10 3 c/mL) in healthy controls. In KTRs with MPA withdrawal, TTV load decreased significantly from a median (interquartile range) of 1.11 × 10 4 c/mL (4.75 × 10 2 -1.92 × 10 5 c/mL) to 5.24 × 10 3 c/mL (6.92 × 10 2 -6.91 × 10 4 c/mL) 4-5 wk after initiation of MPA withdrawal ( P = 0.003). In patients with MPA withdrawal, TTV load was significantly inversely correlated with COVID-19 or SARS-CoV-2-specific antibodies 4 wk and 3 mo postvaccination ( P = 0.009 and P = 0.004). CONCLUSIONS: TTV load reflects changes in immunosuppressive therapy even late after transplantation, supporting its use to monitor immunocompetence in KTRs.


Asunto(s)
COVID-19 , Trasplante de Riñón , Torque teno virus , Humanos , Trasplante de Riñón/efectos adversos , Vacunas contra la COVID-19 , Carga Viral , Terapia de Inmunosupresión , Receptores de Trasplantes , ADN Viral
4.
EMBO Rep ; 24(5): e57162, 2023 05 04.
Artículo en Inglés | MEDLINE | ID: mdl-36951170

RESUMEN

Throughout the SARS-CoV-2 pandemic, limited diagnostic capacities prevented sentinel testing, demonstrating the need for novel testing infrastructures. Here, we describe the setup of a cost-effective platform that can be employed in a high-throughput manner, which allows surveillance testing as an acute pandemic control and preparedness tool, exemplified by SARS-CoV-2 diagnostics in an academic environment. The strategy involves self-sampling based on gargling saline, pseudonymized sample handling, automated RNA extraction, and viral RNA detection using a semiquantitative multiplexed colorimetric reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay with an analytical sensitivity comparable with RT-qPCR. We provide standard operating procedures and an integrated software solution for all workflows, including sample logistics, analysis by colorimetry or sequencing, and communication of results. We evaluated factors affecting the viral load and the stability of gargling samples as well as the diagnostic sensitivity of the RT-LAMP assay. In parallel, we estimated the economic costs of setting up and running the test station. We performed > 35,000 tests, with an average turnover time of < 6 h from sample arrival to result announcement. Altogether, our work provides a blueprint for fast, sensitive, scalable, cost- and labor-efficient RT-LAMP diagnostics, which is independent of potentially limiting clinical diagnostics supply chains.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , COVID-19/diagnóstico , COVID-19/epidemiología , Prueba de COVID-19 , Técnicas de Laboratorio Clínico/métodos , Pandemias/prevención & control , Sensibilidad y Especificidad , ARN Viral/genética
6.
Clin Chim Acta ; 509: 79-82, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32526218

RESUMEN

BACKGROUND: Besides SARS-CoV-2 RT-PCR testing, serological testing is emerging as additional option in COVID-19 diagnostics. Aim of this study was to evaluate novel immunoassays for detection of SARS-CoV-2 antibodies in human plasma. METHODS: Using EDITM Novel Coronavirus COVID-19 Enzyme Linked Immunosorbent Assays (ELISAs), we measured SARS-CoV-2 IgM and IgG antibodies in 64 SARS-CoV-2 RT-PCR confirmed COVID-19 patients with serial blood samples (n = 104) collected at different time points from symptom onset. Blood samples from 200 healthy blood donors and 256 intensive care unit (ICU) patients collected before the COVID-19 outbreak were also used. RESULTS: The positivity rates in the COVID-19 patients were 5.9% for IgM and 2.9% for IgG ≤ 5 days after symptom onset; Between day 5 and day 10 the positivity rates were 37.1% for IgM and 37.1% for IgG and rose to 76.4% for IgM and 82.4% for IgG after > 10-15 days. After 15-22 days the "true" positivity rates were 94.4% for IgM and 100% for IgG. The "false" positivity rates were 0.5% for IgM and 1.0% for IgG in the healthy blood donors, 1.6% for IgM and 1.2% for IgG in ICU patients. CONCLUSIONS: This study shows high "true" vs. low "false" positivity rates for the EDITM SARS-CoV-2 IgM and IgG ELISAs.


Asunto(s)
Anticuerpos Antivirales/sangre , Betacoronavirus , Infecciones por Coronavirus/sangre , Inmunoglobulina G/sangre , Inmunoglobulina M/sangre , Neumonía Viral/sangre , Pruebas Serológicas/normas , Anciano , Anciano de 80 o más Años , Betacoronavirus/aislamiento & purificación , COVID-19 , Infecciones por Coronavirus/diagnóstico , Ensayo de Inmunoadsorción Enzimática/métodos , Ensayo de Inmunoadsorción Enzimática/normas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pandemias , Neumonía Viral/diagnóstico , SARS-CoV-2 , Pruebas Serológicas/métodos
7.
Clin Chim Acta ; 509: 18-21, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32485155

RESUMEN

BACKGROUND: Here, we report on a head-to-head comparison of the fully-automated Elecsys® Anti-SARS-CoV-2 immunoassay with the EDITM enzyme linked immunosorbent assays (ELISA) for the detection of SARS-CoV-2 antibodies in human plasma. METHODS: SARS-CoV-2 antibodies were measured with the Elecsys® assay and the EDITM ELISAs (IgM and IgG) in 64 SARS-CoV-2 RT-PCR confirmed COVID-19 patients with serial blood samples (n = 104) collected at different time points from symptom onset. Blood samples from 200 healthy blood donors and 256 intensive care unit (ICU) patients collected before the COVID-19 outbreak were also used. RESULTS: In COVID-19 patients, the percentage of positive results rose with time from symptom onset, peaking to positivity rates after 15-22 days of 100% for the Elecsys® assay, of 94% for the EDITM IgM-ELISA and of 100% for the EDITM IgG ELISA. In the 104 blood samples, the agreement between positive/negative classifications of the Elecsys® assay and the EDITM ELISAs (IgM or IgG) was 90%. The false positivity rates in the healthy blood donors and the ICU patients were < 1% for the Elecsys® assay and < 3% for the EDITM ELISAs. CONCLUSIONS: Our results indicate a high sensitivity and specificity for the Elecsys® assay and an acceptable agreement with the EDITM ELISAs.


Asunto(s)
Anticuerpos Antivirales/sangre , Betacoronavirus , Técnicas de Laboratorio Clínico/métodos , Técnicas de Laboratorio Clínico/normas , Infecciones por Coronavirus/sangre , Infecciones por Coronavirus/diagnóstico , Neumonía Viral/sangre , Neumonía Viral/diagnóstico , Betacoronavirus/aislamiento & purificación , COVID-19 , Ensayo de Inmunoadsorción Enzimática/métodos , Ensayo de Inmunoadsorción Enzimática/normas , Femenino , Humanos , Inmunoensayo/métodos , Inmunoensayo/normas , Masculino , Pandemias , SARS-CoV-2 , Pruebas Serológicas/métodos , Pruebas Serológicas/normas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...